1 Blindleistungskompensation
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Blindleistungskompensation
-
2 Online-Dienst
- обслуживание "он-лайн"
обслуживание "он-лайн"
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
on-line service
Service providing an active connection with a communications network. (Source: DBMDE)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Online-Dienst
См. также в других словарях:
active network — aktyvusis keturpolis statusas T sritis fizika atitikmenys: angl. active network vok. aktiver Vierpol, m rus. активный четырёхполюсник, m pranc. quadripôle actif, m … Fizikos terminų žodynas
Active networking — is a communication pattern that allows packets flowing through a telecommunications network to dynamically modify the operation of the network. How it works The active network architecture is composed of execution environments (similar to a unix… … Wikipedia
Network administrator — Network engineer redirects here. For other uses, see Network engineering (disambiguation). A network administrator, network analyst or network engineer is a person responsible for the maintenance of computer hardware and software that comprises a … Wikipedia
Network isolator — Network isolators are installed as part of a copper Ethernet system, as galvanic isolators. Network data continues to be transmitted across an electrically non conducting barrier, through the applied principle of electromagnetic induction,… … Wikipedia
Network Instruments — develops software and hardware solutions for analyzing and managing network and application performance, such as network analyzers. They were founded in 1994, and are headquartered in Minneapolis, Minnesota. The mainstay product of Network… … Wikipedia
Active Directory — (AD) is a directory service created by Microsoft for Windows domain networks. It is included in most Windows Server operating systems. Server computers on which Active Directory is running are called domain controllers. Active Directory serves as … Wikipedia
Network detector — Network detectors or network discovery software are computer programs that facilitate detection of wireless LANs using the 802.11b, 802.11a and 802.11g WLAN standards.[1] Discovering networks may be done through active as well as passive scanning … Wikipedia
Network congestion avoidance — is a process used in computer networks to avoid congestion.The fundamental problem is that all network resources are limited, including router processing time and link throughput. Eg.: *today s (2006) Wireless LAN effective bandwidth throughput… … Wikipedia
Active dynamic filtering — Active dynamic filtering, ADF, is a three phase power electronics based power flow control technology that can effectively be used to isolate and remove electrical behaviours that cause excess losses and disruptions in the electrical… … Wikipedia
Network planning and design — is an iterative process, encompassing topological design, network synthesis, and network realization, and is aimed at ensuring that a new network or service meets the needs of the subscriber and operator.[1] The process can be tailored according… … Wikipedia
Network Access Protection — (NAP) is a Microsoft technology for controlling network access of a computer host based on the system health of the host, first introduced in Windows Server 2008. With Network Access Protection, system administrators of an organization s computer … Wikipedia